Software available for Fiery Network Controller for DocuColor 242/252/260 v2.0 
Fiery PatchPrint Drivers

Patch Order

Patch ID

Short Description

File Size

Date Published

Exclusive Install

File Name: ProdID.ps
File Size: 209.44 KB
Date Posted: 3/18/2009
Date Published:
6/24/2011
Criticality: Critical
Description: Product Identification Patch
ID: PRODID
Installation Order:
1
Notes:  
This patch is a Product Identifier (ID) patch, designed to add a unique identifier into the Fiery system. Once the Product ID patch is successfully installed, the Fiery System will be compatible with future "Smart" patches.

After installation, the Product ID patch will appear on the Fiery Configuration sheet in the "Installed updates" section or on the System Updates Log. The name will be displayed simply as "ProdID".

This Product ID patch will serve as a prerequisite to all future smart patches. If the Product ID patch is not installed, all subsequent Smart patches will not install. For more information regarding this patch, please contact your support representative.

Patch Installation Instructions:
1. Using Command Workstation, import the patch file ProdID.ps to the "Direct" queue of the Fiery server.
2. Allow approximately 40 secs and/or when the file is done processing after the patch file is imported before rebooting the system. This will ensure the patch file is completely processed.
3. From either Command Workstation or the Fiery LCD, select "Shut Down" and then "Reboot System"
4. When the Fiery has come to Idle, verify the patch ID on the Configuration Page/System Update Log.
5. It should contain the patch name "ProdID".
Requires exclusive install
4669

Download:  ProdID.ps
File Name: 1-U8E58.ps
File Size: 31.19 MB
Date Posted: 10/5/2007
Date Published:
2/12/2013
Criticality: Critical
Description: Composite patch for DocuColor 242/252/260 1.0
ID: 1-U8E58
Installation Order:
2
Notes:  
Issues that are fixed with this patch:
1-QO0GQ
1-RC64O
1-RO9M5
1-S1SVY
1-S5MOX
1-RQJ69
1-RQJK9
1-RQMC5
1-RS2KP
1-S7KOD
1-S94XF
1-R7A1N
1-RSNQA
1-SBDEP
1-R9LAP
1-RLAFY
1-RWNH9
1-RX6G5
1-SN9KW
1-RU61H
1-SBDEL
1-S35T1
1-RNIB0
1-SUNGP
1-TOJP6
1-TDCRL
1-TGSJF
1-T2CJQ
Requires exclusive install
3394

Required Software:
PRODID 

Download:  1-U8E58.ps
File Name: 1-18SMZM.ps
File Size: 66.46 MB
Date Posted: 1/16/2012
Date Published:
2/12/2013
Criticality: Critical
Description: Composite patch for Fiery Network Controller for DocuColor 242/252/260 v2.0.
ID: 1-18SMZM
Installation Order:
3
Notes:  
Prerequisites:

PRODID
1-U8E58

Patch installation instruction

1. Make sure that the Fiery is Idle.

2. Import the patch file 1-18SMZM.ps using Command Workstation to the Direct queue.

3. You must wait until the file finishes processing and CWS or LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4. From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5. Wait until the Fiery comes to Idle and print the configuration page.

6. Verify that the System Updates Log contains the patch number 1-18SMZM.
Requires exclusive install
8120

Required Software:
1-U8E58 , PRODID 

Download:  1-18SMZM.ps
File Name: 1-1E21N4.ps
File Size: 42.30 MB
Date Posted: 2/16/2012
Date Published:
2/12/2013
Criticality: Critical
Description: Composite Patch 3 for Fiery Network Controller for DocuColor 242/252/260 v2.0.
ID: 1-1E21N4
Installation Order:
4
Notes:  
Before installing 1-1E21N4.ps

1 Known issues listed below, read before installing 1-1E21N4.ps patch:
This patch obsoletes all the individual patches.

2 The following prerequisite(s) must be installed in the order specified before applying the 1-1E21N4.ps patch:
ProdID.ps
1-U8E58
1-18SMZM

3 Do NOT install any of the following patch(es) after installing the 1-1E21N4.ps patch. If you must install any of the patch(es) below, do so before installing the 1-1E21N4.ps patch:
None.

4 This patch is exclusive, it must be installed by itself, and the server must be rebooted or restarted once. After that, other patches can be applied to the server.

Patch installation instructions

1 Make sure that the Fiery controller has reached Idle.

2 Import the patch file 1-1E21N4.ps using Command WorkStation to the Direct connection.

3 You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait 3 minutes for complete installation of patch.

4 From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5 Wait until the Fiery controller reaches Idle and print the configuration page.

6 Verify that the Update Info section contains the patch number 1-1E21N4.
Requires exclusive install
8609

Required Software:
1-U8E58 , PRODID , 1-18SMZM 

Download:  1-1E21N4.ps
File Name: 1-13LK3J.ps
File Size: 21.31 MB
Date Posted: 2/17/2012
Date Published:
2/13/2013
Criticality: Critical
Description: FreeFlow 8.0 enablement patch for Docu color 242-252-260 v2.0
ID: 1-13LK3J
Installation Order:
5
Notes:  
Prerequisite:

PRODID

Installation Instructions:

1. Import the patch file 1-13LK3J.ps with CWS to the Direct queue.
2. You should wait approximately 60 secs and when the file is done processing after the patch file is imported before rebooting the system. This will ensure the patch file is completely processed.
3. From CWS select Reboot System.
4. Wait until the Fiery has come to idle and print out the configuration page.
5. Verify the Update Info section. It should contain the patch number 1-13LK3J.

Note: This patch is Exclusive which means it must be installed independently and the server rebooted/restarted once. After which, other patches can be applied to the server.
Requires exclusive install
5500

Required Software:
PRODID 

Download:  1-13LK3J.ps
File Name: 1-19AZVM.ps
File Size: 1.02 MB
Date Posted: 2/18/2012
Date Published:
2/13/2013
Criticality: Critical
Description: Job ticket media type displays incorrect information when printing to the Fiery from FreeFlow MakeReady
ID: 1-19AZVM
Installation Order:
6
Notes:  
Prerequisite:

PRODID
1-13LK3J

Patch installation instruction.

1. Make sure that the Fiery is Idle.

2. Import the patch file 1-19AZVM.ps using Command Workstation to the Direct queue.

3. You must wait until the file finishes processing and CWS or LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4. From Command WorkStation, choose Server, selct Reboot Server, or from the Fiery LCD, select Shut down, select Reboot System.

5. Wait until the Fiery comes to Idle and print the configuration page.

6. Verify that the System Update Log contains the patch number 1-19AZVM.
Requires exclusive install
6821

Required Software:
PRODID , 1-13LK3J 

Download:  1-19AZVM.ps
File Name: 1-1CNL1W.ps
File Size: 1.03 MB
Date Posted: 2/19/2012
Date Published:
2/13/2013
Criticality: Critical
Description: A Job Submission error occurs when mixed media job with custom media type stocks is submitted through FreeFlow Makeready Application.
ID: 1-1CNL1W
Installation Order:
7
Notes:  
Before installing 1-1CNL1W.ps

1. Known issues listed below, read before installing 1-1CNL1W.ps patch:
None.
2. The following prerequisite(s) must be installed in the order specified before applying the 1-1CNL1W.ps patch:

PRODID
1-13LK3J

3. This patch is exclusive, it must be installed by itself, and the server must be rebooted or restarted once. After that, other patches can be applied to the server.

Patch installation instructions:

1. Make sure that the Fiery controller has reached Idle.
2. Import the patch file 1-1CNL1W.ps using Command WorkStation to the Direct connection.
3. You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait 2 minutes for complete installation of patch.
4. From Command WorkStation, choose Server-> Reboot Server, or from the Fiery LCD, select Shut down -> Reboot System.
5. Wait until the Fiery controller reaches Idle and print the configuration page.
6. Verify that the System Updates Log contains the patch number 1-1CNL1W.
Requires exclusive install
8259

Required Software:
PRODID , 1-13LK3J 

Download:  1-1CNL1W.ps
File Name: 1-1H1YIQ.ps
File Size: 15.29 MB
Date Posted: 11/2/2012
Date Published:
2/13/2013
Criticality: Critical
Description: Composite Patch 4 for Fiery Network Controller for DocuColor 242/252/260 v2.0.
ID: 1-1H1YIQ
Installation Order:
8
Notes:  
Before installing 1-1H1YIQ.ps

1 Known issues listed below, read before installing 1-1H1YIQ.ps patch:
Apache version upgraded to 2.2.22.
OpenSSL version upgraded to 0.9.8q.
PHP version upgraded to 5.3.15.

2 If any prerequisites listed below, they must be installed in the order specified before applying the 1-1H1YIQ.ps patch:
ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-13LK3J
1-19AZVM
1-1CNL1W

3 Do NOT install any of the following patch(es) after installing the 1-1H1YIQ.ps patch. If you must install any of the patch(es) below, do so before installing the 1-1H1YIQ.ps patch:
None.

4 This patch is exclusive, it must be installed by itself, and the server must be rebooted or restarted once. After that, other patches can be applied to the server.

Patch installation instruction

1 Make sure that the Fiery is Idle.

2 Import the patch file 1-1H1YIQ.ps using Command Workstation to the Direct queue.

3 You must wait until the file finishes processing and Command WorkStation or LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4 From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5 Wait until the Fiery comes to Idle and print the configuration page.

6 Verify that the Update Info section contains the patch number 1-1H1YIQ.
Requires exclusive install
9939

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-13LK3J , 1-19AZVM , 1-1CNL1W 

Download:  1-1H1YIQ.ps
File Name: 1-1FLFQA.ps
File Size: 48.19 MB
Date Posted: 12/5/2012
Date Published:
2/13/2013
Criticality: Critical
Description: Patch to address printing of particular files causes Fiery to hang in parsing.
ID: 1-1FLFQA
Installation Order:
9
Notes:  
Before installing 1-1FLFQA.ps

1. Known issues listed below, read before installing 1-1FLFQA.ps patch:
None.

2. If any prerequisites listed below, they must be installed in the order specified before applying the 1-1FLFQA.ps patch:
ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-13LK3J
1-19AZVM
1-1CNL1W
1-1H1YIQ

3. Do NOT install any of the following patch(es) after installing the 1-1FLFQA.ps patch. If you must install any of the patch(es) below, do so before installing the 1-1FLFQA.ps patch:
None.

4. This patch is exclusive, it must be installed by itself, and the server must be rebooted or restarted once. After that, other patches can be applied to the server.


Patch installation instruction

1. Make sure that the Fiery is Idle.

2. Import the patch file 1-1FLFQA.ps using Command Workstation to the Direct queue.

3. You must wait until the file finishes processing and Command WorkStation or LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4. From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5. Wait until the Fiery comes to Idle and print the configuration page.

6. Verify that the Update Info section contains the patch number 1-1FLFQA.
Requires exclusive install
10054

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-13LK3J , 1-19AZVM , 1-1CNL1W , 1-1H1YIQ 

Download:  1-1FLFQA.ps
File Name: 1-1E9HUL.ps
File Size: 295.89 MB
Date Posted: 2/15/2012
Date Published:
11/2/2012
Criticality: Recommended
Description: EFIGS PCL 64 bit drivers to support Windows 2K, XP and VISTA.
ID: 1-1E9HUL
Installation Order:
10
Notes:  
Before installing 1-1E9HUL.ps

1 Known issues listed below, read before installing 1-1E9HUL.ps patch:

None.

2 The following prerequisite(s) must be installed in the order specified before applying the 1-1E9HUL.ps patch:

PRODID
1-U8E58
1-18SMZM
1-1E21N4

3 This patch is exclusive, it must be installed by itself, and the server must be rebooted or restarted once. After that, other patches can be applied to the server.

Patch installation instructions

1 Make sure that the Fiery controller has reached Idle.

2 Import the patch file 1-1E9HUL.ps using Command WorkStation to the Direct connection.

3 You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait 2 minutes for complete installation of patch.

4 From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5 Wait until the Fiery controller reaches Idle and print the configuration page.

6 Verify that the System Update Log contains the patch number 1-1E9HUL.
Requires exclusive install
8599

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 

Download:  1-1E9HUL.ps
File Name: 1-1IJ6ZK.ps
File Size: 15.64 MB
Date Posted: 1/16/2013
Date Published:
2/18/2013
Criticality: Critical
Description: Fiery patch to address security vulnerabilities.
ID: 1-1IJ6ZK
Installation Order:
11
Notes:  
Before installing 1-1IJ6ZK.ps

1. Known issues listed below, read before installing 1-1IJ6ZK.ps patch:
Apache version is upgraded to 2.2.23.
PHP version is upgraded to 5.3.19.
OpenSSL version is upgraded to 0.9.8x.

2. The following prerequisite(s) must be installed in the order specified before applying the 1-1IJ6ZK.ps patch:

ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-13LK3J
1-19AZVM
1-1CNL1W
1-1H1YIQ
1-1FLFQA

3. This patch is exclusive, it must be installed by itself, and the server must be rebooted once. After that, other patches can be applied to the server.


Patch installation instructions

1. Make sure that the Fiery controller has reached Idle.

2. Import the patch file 1-1IJ6ZK.ps using Command WorkStation to the Direct connection.

3. You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4. From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5. Wait until the Fiery controller reaches Idle and print the configuration page.

6. Verify that the System Update Log contains the patch number 1-1IJ6ZK.
Requires exclusive install
10232

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E9HUL , 1-1E21N4 , 1-13LK3J , 1-19AZVM , 1-1CNL1W , 1-1H1YIQ , 1-1FLFQA 

Download:  1-1IJ6ZK.ps
File Name: FIT100698425.ps
File Size: 1.18 MB
Date Posted: 10/31/2014
Date Published:
9/2/2017
Criticality: Critical
Description: Patch to address Shellshock vulnerability
ID: FIT100698425
Installation Order:
12
Notes:  
Please see the release note for details.
13203

Download:  FIT100698425.ps
File Name: 1-1J9XUG.ps
File Size: 1.28 MB
Date Posted: 3/14/2013
Date Published:
3/20/2013
Criticality: Recommended
Description: Fiery patch to upgrade Open SSL version.
ID: 1-1J9XUG
Installation Order:
13
Notes:  
Before installing 1-1J9XUG.ps

1 Known issues listed below, read before installing 1-1J9XUG.ps patch:
OpenSSL version is upgraded to 0.9.8y.

2 The following prerequisite(s) must be installed in the order specified before applying the 1-1J9XUG.ps patch:

ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-13LK3J
1-19AZVM
1-1CNL1W
1-1H1YIQ
1-1FLFQA
1-1IJ6ZK

3 This patch is exclusive, it must be installed by itself, and the server must be rebooted once. After that, other patches can be applied to the server.

Patch installation instructions

1 Make sure that the Fiery controller has reached Idle.

2 Import the patch file 1-1J9XUG.ps using Command WorkStation to the Direct connection.

3 You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4 From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5 Wait until the Fiery controller reaches Idle and print the configuration page.

6 Verify that the System Update Log contains the patch number 1-1J9XUG.
Requires exclusive install
10485

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-13LK3J , 1-19AZVM , 1-1CNL1W , 1-1H1YIQ , 1-1FLFQA , 1-1IJ6ZK 

Download:  1-1J9XUG.ps
File Name: 1-1J9XON.ps
File Size: 2.68 MB
Date Posted: 3/18/2013
Date Published:
3/20/2013
Criticality: Recommended
Description: Fiery patch to address scan share folder issue.
ID: 1-1J9XON
Installation Order:
14
Notes:  
Before installing 1-1J9XON.ps

1.Known issues listed below, read before installing 1-1J9XON.ps patch:
None

2.The following prerequisite(s) must be installed in the order specified before applying the 1-1J9XON.ps patch:

ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-13LK3J
1-19AZVM
1-1CNL1W
1-1H1YIQ
1-1FLFQA
1-1IJ6ZK

3.This patch is exclusive, it must be installed by itself, and the server must be rebooted once. After that, other patches can be applied to the server.

Patch installation instructions

1.Make sure that the Fiery controller has reached Idle.

2.Import the patch file 1-1J9XON.ps using Command WorkStation to the Direct connection.

3.You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4.From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5.Wait until the Fiery controller reaches Idle and print the configuration page.

6.Verify that the System Update Log contains the patch number 1-1J9XON
10497

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-13LK3J , 1-19AZVM , 1-1CNL1W , 1-1H1YIQ , 1-1FLFQA , 1-1IJ6ZK 

Download:  1-1J9XON.ps
File Name: 1-1KJPUM.ps
File Size: 31.43 KB
Date Posted: 9/29/2013
Date Published:
10/7/2013
Criticality: Recommended
Description: Fiery patch to address scan template slash is missing between folders.
ID: 1-1KJPUM
Installation Order:
15
Notes:  
Before installing 1-1KJPUM.ps

1.Known issues listed below, read before installing 1-1KJPUM.ps patch:
None.

2.The following prerequisite(s) must be installed in the order specified before applying the 1-1KJPUM.ps patch:
ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-1H1YIQ

3.This patch is not exclusive, it can be applied to the server along with other patches concurrently, and one server reboot or restart is sufficient for all patches to take effect on the system.

Patch installation instructions

1.Make sure that the Fiery controller has reached Idle.

2.Import the patch file 1-1KJPUM.ps using Command WorkStation to the Direct connection.

3.You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4.From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5.Wait until the Fiery controller reaches Idle and print the configuration page.

6.Verify that the System Update Log contains the patch number 1-1KJPUM.
11327

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-1H1YIQ 

Download:  1-1KJPUM.ps
File Name: FIT192222.ps
File Size: 29.77 MB
Date Posted: 12/12/2013
Date Published:
1/27/2014
Criticality: Recommended
Description: Fiery patch to address security vulnerabilities.
ID: FIT192222
Installation Order:
16
Notes:  
Before installing FIT192222.ps

1.Known issues listed below, read before installing FIT192222.ps patch:
Apache version is upgraded to 2.2.25.
PHP version is upgraded to 5.3.27.
Samba version is upgraded to 3.5.21.
OpenSSL version is upgraded to 0.9.8y.
This patch obsoletes 1-1J9XUG and 1-1IJ6ZK patches

2.The following prerequisite(s) must be installed in the order specified before applying the FIT192222.ps patch:
ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-1H1YIQ
1-1J9XON

3.This patch is exclusive, it must be installed by itself, and the server must be rebooted once. After that, other patches can be applied to the server.

Patch installation instructions

1.Make sure that the Fiery controller has reached Idle.

2.Import the patch file FIT192222.ps using Command WorkStation to the Direct connection.

3.You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4.From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5.Wait until the Fiery controller reaches Idle and print the configuration page.

6.Verify that the System Update Log contains the patch number FIT192222.
Requires exclusive install
11707

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-1H1YIQ , 1-1J9XON 

Download:  FIT192222.ps
File Name: FIT197799.ps
File Size: 1.72 MB
Date Posted: 12/18/2013
Date Published:
1/31/2014
Criticality: Recommended
Description: Fiery patch to address incorrect date format and sorting of Fiery print job display on Engine LCD Panel.
ID: FIT197799
Installation Order:
17
Notes:  
Before installing FIT197799.ps

1.Known issues listed below, read before installing FIT197799.ps patch:
None.

2.The following prerequisite(s) must be installed in the order specified before applying the FIT197799.ps patch:
ProdID
1-U8E58
1-18SMZM
1-1E21N4
1-1H1YIQ

3.This patch is exclusive, it must be installed by itself, and the server must be rebooted once. After that, other patches can be applied to the server.

Patch installation instructions

1.Make sure that the Fiery controller has reached Idle.

2.Import the patch file FIT197799.ps using Command WorkStation to the Direct connection.

3.You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4.From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5.Wait until the Fiery controller reaches Idle and print the configuration page.

6.Verify that the System Update Log contains the patch number FIT197799.
Requires exclusive install
11727

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-1H1YIQ 

Download:  FIT197799.ps
File Name: FIT224377.ps
File Size: 34.95 MB
Date Posted: 10/9/2014
Criticality: Recommended
Description: Fiery patch to address Security vulnerabilities.
ID: FIT224377
Installation Order:
18
Notes:  
Before installing FIT224377.ps

1 Known issues listed below, read before installing FIT224377.ps patch:
Apache version is upgraded to 2.2.29
PHP version is upgraded to 5.3.29
Samba version is upgraded to 3.5.22.
OpenSSL version is upgraded to 0.9.8zb

2 The following prerequisite(s) must be installed in the order specified before applying the FIT224377.ps patch:
ProdID
1-1U8E58
1-18SMZM
1-1E21N4
1-1H1YIQ
1-1J9XUG
1-1J9XON
1-1KJPUM
FIT197799
FIT192222


3 This patch is exclusive, it must be installed by itself, and the server must be rebooted once. After that, other patches can be applied to the server.

Patch installation instructions

1 Make sure that the Fiery controller has reached Idle.

2 Import the patch file FIT224377.ps using Command WorkStation to the Direct Queue.

3 You must wait until the file finishes processing and Command WorkStation or the LCD show Idle. This ensures the patch file is completely processed. User should wait one minute for complete installation of patch.

4 From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5 Wait until the Fiery controller reaches Idle and print the configuration page.

6 Verify that the System Update Log contains the patch number FIT224377
Requires exclusive install
12962

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-1H1YIQ , 1-1J9XUG , 1-1J9XON , 1-1KJPUM , FIT192222 , FIT197799 

Download:  FIT224377.ps
File Name: FIT100700009.ps
File Size: 39.20 KB
Date Posted: 10/31/2014
Date Published:
11/11/2014
Criticality: Recommended
Description: Fiery Patch to address scan to SMB issue.
ID: FIT100700009
Installation Order:
19
Notes:  
Before installing FIT100700009.ps

1. Known issues listed below, read before installing FIT100700009.ps patch:
None.

2. The following prerequisite(s) must be installed in the order specified before applying the FIT100700009.ps patch:
ProdID
1-1U8E58
1-18SMZM
1-1E21N4
1-1H1YIQ
1-1J9XUG
1-1J9XON
1-1KJPUM
FIT197799
FIT192222
FIT224377

3. Do NOT install any of the following patch(es) after installing the FIT100700009.ps patch. If you must install any of the patch(es) below, do so before installing the FIT100700009.ps patch:
None.

4. This patch is not exclusive, it can be installed along with other patches concurrently, and one server Reboot or Restart is sufficient for all patches to take effect on the system.

Patch installation instructions

1. Make sure that the Fiery controller has reached Idle.

2. Import the patch file FIT100700009.ps using Command WorkStation to the Direct connection.

3. You must wait until the file finishes processing and Command WorkStation or the LCD show Idle.

4. From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5. Wait until the Fiery controller reaches Idle and print the configuration page.

6. Verify that the Update Info section contains the patch number FIT100700009.
13202

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-1H1YIQ , 1-1J9XUG , 1-1J9XON , 1-1KJPUM , FIT192222 , FIT197799 , FIT224377 

Download:  FIT100700009.ps
File Name: FIT100735219.ps
File Size: 3.89 MB
Date Posted: 12/11/2014
Date Published:
12/19/2014
Criticality: Recommended
Description: Patch to address incompatibility issue between the Configure application and JRE 1.7u51.
ID: FIT100735219
Installation Order:
20
Notes:  
Before installing FIT100735219.ps

1. Known issues listed below, read before installing FIT100735219.ps patch:
None.

2. The following prerequisite(s) must be installed in the order specified before applying the FIT100735219.ps patch:
ProdID
1-1U8E58
1-18SMZM
1-1E21N4
1-1H1YIQ
1-1J9XUG
1-1J9XON
1-1KJPUM

3. Do NOT install any of the following patch(es) after installing the FIT100735219.ps patch. If you must install any of the patch(es) below, do so before installing the FIT100735219.ps patch:
None.

4. This patch is not exclusive, it can be installed along with other patches concurrently, and one server Reboot or Restart is sufficient for all patches to take effect on the system.

Patch installation instructions

1. Make sure that the Fiery controller has reached Idle.

2. Import the patch file FIT100735219.ps using Command WorkStation to the Direct connection.

3. You must wait until the file finishes processing and Command WorkStation or the LCD show Idle.

4. From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5. Wait until the Fiery controller reaches Idle and print the configuration page.

6. Verify that the Update Info section contains the patch number FIT100735219.
13371

Required Software:
1-U8E58 , PRODID , 1-18SMZM , 1-1E21N4 , 1-1H1YIQ , 1-1J9XUG , 1-1J9XON , 1-1KJPUM 

Download:  FIT100735219.ps
File Name: FIT101063608.ps
File Size: 14.14 MB
Date Posted: 1/5/2016
Date Published:
1/27/2016
Criticality: Recommended
Description: Fiery Patch to address the Security vulnerabilities.
ID: FIT101063608
Installation Order:
21
Notes:  
Before installing FIT101063608.ps

1. Known issues listed below, read before installing FIT101063608.ps patch:
Apache version is upgraded to 2.2.29
PHP version is upgraded to 5.4.41
OpenSSL version is upgraded to 0.9.8zf
Samba version is upgraded to 3.0.31

2. The following prerequisite(s) must be installed in the order specified before applying the FIT101063608.ps patch:
None.

3. Do NOT install any of the following patch(es) after installing the FIT101063608.ps patch. If you must install any of the patch(es) below, do so before installing the FIT101063608.ps patch:
None.

4. This patch is exclusive, it must be installed by itself, and the server must be rebooted or restarted once. After that, other patches can be applied to the server.

Patch installation instructions

1. Make sure that the Fiery controller has reached Idle.

2. Import the patch file FIT101063608.ps using Command WorkStation to the Direct connection.

3. You must wait until the file finishes processing and Command WorkStation or the LCD show Idle.

4. From Command WorkStation, choose Server, Reboot Server, or from the Fiery LCD, select Shut down, Reboot System.

5. Wait until the Fiery controller reaches Idle and print the configuration page.

6. Verify that the Update Info section contains the patch number FIT101063608.
Requires exclusive install
15293

Download:  FIT101063608.ps